DT-6061 Embedded Network Processor Platform User's Manual RELEASE.VERSION 17.1 379 Campus Drive, Suite 100 Somerset, NJ 08873 fax: 732 6
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 10 Application Name Description X25PAD Eliminates the need
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 11 2 PHYSICAL DESCRIPTION Figure 2: DT-6061 Front View 2.
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 12 2.4 10BASE-T LAN These two interfaces require a standar
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 13 3 INSTALLATION This chapter contains the steps required
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 14 DT-6061 unit(s) AC to DC power supply(s). –48 VDC i
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 15 5) Attach console cable by plugging 1 end of the RJ45
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 16 4 CABLING 4.1 SERIAL CONSOLE CONNECTION AND CONFIGURATI
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 17 Important! A modular cable with “SPECIAL WIRING” can
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 18 5 QUICK S TART C ONFIGURATION G UIDE There are two leve
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 19 5.3 APPLICATION INSTALLATION This action requires that
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 2 TABLE OF CONTENTS TABLE OF CONTENTS ...
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 20 6 DT-6061 C OMMAND R EFERENCE All DT-6XXX software is
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 21 The banner and some of the parameters of the snmp com
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 22 Table 5: Command Reference table Section NumberCategory
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 23 6.3 SYSTEM PLATFORM CONFIGURATION – NON IP NETWORK COMM
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 24 a newline (enter). The user is again prompted for a lin
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 25 6.3.7 CHANGE PASSWORD - CHGPASS Syntax: chgpass OLD=<
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 26 6.4 SYSTEM PLATFORM CONFIGURATION – IP NETWORK RELATED
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 27 The IP address and subnet mask are used to determine wh
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 28 The optional simplex parameter can be used to switch th
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 29 Each ipaddr<n> field is the IP address of a Domai
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 3 6.3.4 System Label Configuration - label...
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 30 If a DT-4XXX or UMI at address 'C' has been
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 31 6.5 SOFTWARE ADMINISTRATION COMMANDS 6.5.1 INSTALLING A
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 32 If parameters are omitted from the command line, instal
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 33 (including its configuration). The type must be the nam
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 34 IP address of the DT-6061 or the configured label. The
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 35 non-volatile memory. There is only one trap=<commun
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 36 6.8 RUN-TIME COMMANDS 6.8.1 DISPLAY CONNECTIONS – DC OR
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 37 reports only connections that are associated with insta
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 38 The cpu subcommand reports CPU utilization by process.
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 39 sclk: 0 0% 113992 eth0: 132 0% 8912
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 4 6.9.3 Automatic Standby Configuration Update – stby cfg.
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 40 6.8.3.6 TRACE ROUTE - DIAG TRACERT OR DIAG TRTE Syntax
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 41 destination. Each router along the path is required to
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 42 The vfy cfg (or vfycfg) command displays each configure
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 43 6.9 HIGH AVAILABILITY OPTION The High Availability opti
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 44 synchronizing, thus disabling the ability to switchover
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 45 standby software in sync with the active. The release n
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 46 the active DT-6061. Either way, registration of the app
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 47 snmp switchover timeout timezone The help comm
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 48 7 APPENDIX A: C ONSOLE C ABLE - S PECIAL W IRING D
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 49 7.1 THE DB9 CONSOLE ADAPTER Some Personal Computers us
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 5 14 End-User License Agreement for Software...
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 50 8 APPENDIX B: SNMP MIB VARIABLE D ATABASE AND T RAP
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 51 MIB Variable Number Name MIB Console Equivalent Acce
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 52 MIB Variable Number Name MIB Console Equivalent Acce
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 53 9 APPENDIX C: TCP/UDP P ORT N UMBERS The DT-6061 use
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 54 10 APPENDIX D: T HE D ISPLAY M EASUREMENTS ( DM) R
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 55 Measurement descriptions: IP 1: The total number of in
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 56 10.2 TCP – DM TCP <DT-6061> dm tcp tcp: TCP 1 12
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 57 TCP 12 2 connections dropped by rexmit timeout TCP 13
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 58 10.3 UDP – DM UDP <DT-6061> dm udp udp: 834716 da
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 59 10.4 ICMP – DM ICMP Note - within the output and inpu
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 6 Table 9: TCP/UDP Port Numbers Used ...
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 60 Measurement descriptions: ICMP 1: The number of ICMP m
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 61 10.5 ETH – DM ETH <tuna: DT-6061> dm eth Name
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 62 11 APPENDIX E: B RIEF D ESCRIPTIONS OF DT-6XXX A PPL
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 63 LoopCare® product. The LoopCare product is the evolutio
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 64 maintenance. Finally, the physical location of these pr
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 65 11.12 ONSITE The ONSITE application for the DT-6XXX Net
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 66 12 APPENDIX F: DT-6061 S PECIFICATIONS Note: Shielded
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 67 12.7 REGULATORY INFORMATION Safety: UL, CSA, Low Volta
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 68 A representative designated by the supplier should coor
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 69 POWER REQUIREMENTS Voltages Current Draw Power Input Re
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 7 Important Safety Instructions The exclamation point with
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 70 13 HARDWARE WARRANTY The warranty period for hardware s
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 71 14.3 SOFTWARE SUPPORT SOFTWARE support is not provided
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 72 14.7 SPECIAL PROVISIONS The SOFTWARE and documentation
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 8 1 INTRODUCTION The DT-6061 (Embedded Network Processor)
DT-6061 User's Manual - Platform (Build 17.1) 12/14/09 Datatek Applications Inc. 9 1.1 MULTIPLE APPLICATION SUPPORT The DT-6061 can support
Comments to this Manuals